Materials science and engineering is a foundation and application, paying equal attention to both theory and practice of discipline, with openness, exploration, the development of the research-oriented teaching reform, the original experimental teaching materials and lecture notes have been unable to meet the demand of experimental teaching, professional instruments and equipment are first-class undergraduate practical teaching and subject construction of the major requirements. Partulab hk force Po material for independent research and development of teaching of undergraduate course teaching of physics research dielectric spectrometer, the instrument will impedance measurement, high temperature furnace, jig, measurement software, touch screen and other integrated into an organic whole, without external impedance analyzer, can independently material dielectric properties measurement, meet the demand of teaching, economical and practical.

Technical specifications

 

Temperature: room temperature to 500

Temperature control precision: ± 1

Measurement frequency: 20Hz ~ 1MHz

Measurement accuracy: 0.05%

Temperature rise of slope: 0 ~ 10 / min (typical values 3 / min)

Measurement conditions: independent measuremen

Measurement environment: high temperature, without vacuum atmosphere

Measuring fixture: single sample fixture of block body

Electrode material: platinum

Control temperature: PID precise control temperature

Instrument communication: USB

Data storage: automatic storage of Excel format

Functional features

Professional dielectric test software can measure the dielectric constant and dielectric loss, the impedance spectroscopy cole-cole diagram

Integration of the design, can complete the material dielectric performance test independently

Single sample block measurement jig, hemisphere + plate electrode, good contact of sample, high measurement accuracy

The dielectric properties of the samples can be measured under normal temperature, high temperature and low frequency.
 
It can measure the quantity of impedance Z, reactance X, admittance Y, electrical conductance G, induction, inductance L, dielectric loss D, etc.
 
The dielectric constant and loss can be directly measured, and the impedance spectroscopy cole-cole diagram can be measured.
 
Integrated design, touch screen control and display, with excellent ease of use;
 
Electric lifting platform, spring electrode system, simple operation, easy to use;
 
The system comes with the temperature calibration function to keep the temperature of the measuring temperature consistent with the actual temperature of the sample.
 
The system adopts PID fuzzy algorithm with precise temperature control, overtemperature protection, one-button self-tuning, fault diagnosis function.
 
It can effectively increase the frequency bandwidth of the test and reduce the communication interference of the furnace wire.